Compsee Apex III Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Čtečky čárových kódů Compsee Apex III. View - Connect, Inc. Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Supported Equipment Manual
for the Apex III and IV Hand Held Terminals manufactured by Compsee
Zobrazit stránku 0
1 2 3 4 5 6 ... 73 74

Shrnutí obsahu

Strany 1 - Supported Equipment Manual

Supported Equipment Manual for the Apex III and IV Hand Held Terminals manufactured by Compsee

Strany 2 - Production

Terminal Setup Click on the Setup application and proceed to the following section entitled Installation for further instructions. Installation The In

Strany 3 - May, 2006 iii

Installation To change the default Destination Location, click on Browse and select a location. Then click on Next. The default folder is PowerNe

Strany 4 - May, 2006

Terminal Setup When the installation is complete, reboot the system to initialize the Twin Client software. a. To reboot the system immediately, cl

Strany 5 - Chapter 1 • Introduction

Quick Start Toolbar Found under the menu bar, the toolbar provides shortcuts to major features. The toolbar can be turned on or off by changing the

Strany 6 - Setup Requirements

Terminal Setup Click on Emulation, select the desired emulation, and click on OK. Setting the Servers The Servers are the Telnet host systems the te

Strany 7 - Release Note

Quick Start Repeat this step for each Telnet server the terminals are required to access. If an error is made in the name, IP Address, IP Port numbe

Strany 8 - Introduction

Terminal Setup Setting Auto-Configuration The configuration download and IP address assignment for each terminal will take place automatically by set

Strany 9 - Chapter 2 • Terminal Setup

Quick Start This powerful software management tool is described in detail in Auto-Configuration. For now, it is sufficient simply to use it for ass

Strany 10 - Installation

Terminal Setup Click on the + sign in front of Terminal/Group Manager to access the default terminal group. Next, click on the New Group icon and us

Strany 11 - May, 2006

Quick Start Downloading Program Files Under the Terminal menu, click on the Send Program Files to Terminal menu option. At the prompt, choose Yes

Strany 12 - Running the Manager

Copyright © 1996 - 2006 by Connect, Inc. All rights reserved. This document may not be reproduced in full or in part, in any form, without prior wri

Strany 13 - Quick Start

Terminal Setup AirLoad Execution Once the terminal reboots, Airloader will automatically search for the Airloader server. If no server is found, the f

Strany 14 - Setting the Servers

Quick Start C:\>IR ON From the terminal type LD, and press Enter. C:\>LD Downloading Configuration Files From the Twin Client Manager select

Strany 15 - Saving the Configuration

Terminal Setup PowerNet © 1991-2006, Connect, Inc. Keypress to Continue Note: The date of 2006 is updated on the terminal at the time of a new rele

Strany 16 - Setting Auto-Configuration

Standard Setup Troubleshooting The following table describes the error messages that will be displayed on the terminal in the event of a download fa

Strany 17 - Terminal/Group Manager

Terminal Setup Then click on the vt100 or vt220 selection, as shown below. Click on OK after the selection is made, and return to the main Twin Cli

Strany 18 - Terminal Setup

Standard Setup Quadrant Mode The scrolling list option defines the rules by which the terminal display is positioned in the larger host display. As

Strany 19 - Downloading Program Files

Terminal Setup Click on OK after the selection is made, and return to the main Twin Client Manager menu. The standard settings tab will now reflect t

Strany 20 - AirLoad Execution

Standard Setup Soft always positions on a quadrant boundary regardless of input field boundaries. Viewing keys are enabled. Hard is the same as

Strany 21 - Quick Start

Terminal Setup Quadrant Mode The scrolling list option defines the rules by which the terminal display is positioned in the larger host display. A

Strany 22 - Starting a Telnet Session

Standard Setup Key Click This check box enables (checked) or disables (unchecked) audible key clicks from the terminal. The default value is on (ch

Strany 23 - Standard Setup

Table of Contents Chapter 1 • Introduction... 1-1 Descrip

Strany 24

Terminal Setup Host 0 IP 206.183.67.155 Port 23__ <F3> Save <F7> Quit Press F3 to save the configurations. Edit Radio Option This f

Strany 25 - 5250 Settings

Standard Setup Authorizing PowerNet Each PowerNet Twin Client will run for 30 minutes at a time without authorization. Uninterrupted operation fo

Strany 26

Terminal Setup Note: In the case of individual licensing for single terminals, all punctuation characters and spaces will be filtered out of the Syste

Strany 27 - 3270 Settings

Standard Setup Use the Machine ID in the pop-up box instead of the original Machine ID to get your Authorization code. If adding users, click o

Strany 28

Terminal Setup Note: This feature only works if there are licenses remaining on the old PC. Supported Equipment Manual • May, 2006 2-26

Strany 29 - Edit Server/Host IPs

Software Management Software Management In addition to providing functions for the download of files to the terminal, the Twin Client Manager also p

Strany 30 - Run Client Emulator

Terminal Setup Synchronizing Configuration Files Click to put a check in the Synchronize Configuration Files box to enable automatic synchronization

Strany 31 - Authorizing PowerNet

Software Management Enter the desired range in the From and To boxes as shown above, and then click on Add. Creating New Groups New groups, with di

Strany 32 - Adding Licenses

Terminal Setup After the Configuration File and all of the other parameters have been set, the group is made active by clicking on the Active check b

Strany 33 - Transferring Licenses

Software Management Setting the Segment Checking the Segment button restricts a terminal group to a range of IP addresses. The IP Address can be any

Strany 34

This page is intentionally blank.iv Supported Equipment Manual • May, 2006

Strany 35 - Software Management

Terminal Setup Then, holding the mouse button down, drag the terminal icon to the desired group as shown next. Release the mouse button, which reassi

Strany 36 - Synchronizing Program Files

Software Management Manual Download of Configuration Files The automated configuration management provided by the Twin Client Manager eliminates the

Strany 37 - Creating New Groups

Terminal Setup This page is intentionally blank. Supported Equipment Manual • May, 2006 2-34

Strany 38 - check box

Chapter 3 • Keypad Configuration Keypad Figures (The keypad figures for the Apex III and IV terminal begin on the following page.)Supported Equipment

Strany 39 - Reassigning Terminals

Keypad Configuration . 0 space 4

Strany 40

Keypad Figures . 0 space 4 5

Strany 41 - Software Management

Keypad Configuration . 0 space 4 5

Strany 42

Keypad Table Keypad Table Key VTERM 3270 5250 a <a> <a> <a> b <b> <b> <b> c <c> <c> <c> d <

Strany 43 - Keypad Figures

Keypad Configuration scan <scan> <scan> <scan> caps <fn><ctrl> <fn><ctrl> <fn><ctrl> ins <fn&

Strany 44 - VT emulation

Keypad Table . period <.> <.> <.> ~ tilde <fn><a> <fn

Strany 45 - 3270 emulation

Chapter 1 • Introduction Description The Apex III and IV hand held terminals feature a full alphanumeric keypad, full graphic display (240 x 160 pix

Strany 46 - 5250 emulation

Keypad Configuration This page is intentionally blank. Supported Equipment Manual • May, 2006 3-8

Strany 47 - Keypad Table

Chapter 4 • Error Message Resolution Guide Twin Client Error Message Resolution Guide Message Reason Solution Reference Tech Note ENTRY TOO LONG

Strany 48 - Keypad Configuration

Error Message Resolution Guide Message Reason Solution Reference Tech Note INVALID KEY; The key pressed is not valid. Ensure that you are

Strany 49 - Keypad Table

Error Message Resolution Guide Message Reason Solution Reference Tech Note Connection ERROR.\nREBOOT MOBILE UNIT; Could not Connect. Veri

Strany 50

Error Message Resolution Guide Message Reason Solution Reference Tech Note TIMEOUT\n\nSending Data; Mobile Unit out of the coverage area. M

Strany 51

Error Message Resolution Guide Message Reason Solution Reference Tech Note Error receiving host\nlist from Server; Bad Protocol detected.

Strany 52

Error Message Resolution Guide Message Reason Solution Reference Tech Note User Count Exceeded.\n Session Ended; Possible authorization iss

Strany 53

Error Message Resolution Guide Message Reason Solution Reference Tech Note Font Loading Error; Could not load the font. Ensure that th

Strany 54

Error Message Resolution Guide Message Reason Solution Reference Tech Note TwinClient Telnet; Prompt. Advisory message. --- TwinClient S

Strany 55

Error Message Resolution Guide Message Reason Solution Reference Tech Note Edit License Key; Menu Option. Advisory message. --- Run S

Strany 56

Introduction Pictures Apex III Apex IV Setup Requirements Installation of PowerNet Twin Client requires, at a minimum, the following: • A Pentium-

Strany 57

Error Message Resolution Guide Message Reason Solution Reference Tech Note REMOVE FROM CRADLE; Remove Mobile Unit from the cradle. Advisor

Strany 58

Error Message Resolution Guide Message Reason Solution Reference Tech Note Printer Not\nResponding; Can not print. Check cable, battery

Strany 59

Error Message Resolution Guide Message Reason Solution Reference Tech Note Domain Name Server\nQuery Sending Error; Mobile Unit out of the co

Strany 60

Error Message Resolution Guide Message Reason Solution Reference Tech Note Host/App/Network\nclosed the session; Customer’s environm

Strany 61

Error Message Resolution Guide Message Reason Solution Reference Tech Note Continue (Y/N)?; Prompt. Advisory message. --- HOST ENTRY; Pr

Strany 62

Error Message Resolution Guide Message Reason Solution Reference Tech Note <BK SP> Sends; Prompt. Advisory message. ---

Strany 63

Error Message Resolution Guide Message Reason Solution Reference Tech Note ANSI Setup; Prompt. Advisory message. --- Control Codes; Prom

Strany 64

Error Message Resolution Guide Message Reason Solution Reference Tech Note User Name; Prompt. Advisory message.

Strany 65

Error Message Resolution Guide Message Reason Solution Reference Tech Note Send Delete; Prompt. Advisory message. --- Send Backspace; P

Strany 66

Error Message Resolution Guide Message Reason Solution Reference Tech Note Reset Options; Prompt. Advisory message. --- Font Si

Strany 67

Accessories Accessories Accessories for the Apex III and IV terminals include: PC Card • User-accessible PC Card Slot (One - Type III or two-2

Strany 68

Error Message Resolution Guide Message Reason Solution Reference Tech Note Long Scans; Prompt. Advisory message. -

Strany 69

Error Message Resolution Guide Message Reason Solution Reference Tech Note All Messages; Prompt.

Strany 70

Error Message Resolution Guide Message Reason Solution Reference Tech Note monarch; Prompt. Advi

Strany 71

Error Message Resolution Guide Message Reason Solution Reference Tech Note Delay: ms; Prompt. Advisory

Strany 72

Error Message Resolution Guide Message Reason Solution Reference Tech Note Wand Simulation; Prompt. Adviso

Strany 73

Introduction This page is intentionally blank. Supported Equipment Manual • May, 2006 1-4

Strany 74

Chapter 2 • Terminal Setup Downloading from the WEB The PowerNet Twin Client software package can be downloaded from the Connect web site at http://w

Komentáře k této Příručce

Žádné komentáře